<?xml version="1.0" encoding="UTF-8"?>
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>Czech and Slovak Ophthalmology</journal-title>
      </journal-title-group>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">456</article-id>
      <article-categories>
        <subj-group>
          <subject>Original article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>First Results and Experience with the iTrace Aberometer</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Beneš</surname>
            <given-names>Pavel</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-9430-0383</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Petrová</surname>
            <given-names>Sylvie</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Veselý</surname>
            <given-names>Petr</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-2195-6349</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Synek</surname>
            <given-names>Svatopluk</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date date-type="pub" publication-format="electronic">
        <day>10</day>
        <month>11</month>
        <year>2015</year>
      </pub-date>
      <issue>6</issue>
      <elocation-id>7</elocation-id>
      <abstract>
        <p>Purpose: To evaluate obtained data by using a relatively novel devices and their results which are important eg. in refractive and cataract surgery. Material and methods: The study included 66 eyes (n = 66). Subjects were represented by 32 women and 1 man whose age was 22.5 years ± 1.2 years (min. 21, max. 26 years) without any signs of potential eye disease. Duration of the study was 3 months. Results were compared with the measurements using the auto-refract-keratro-tono-pachymeter (TRK 1P, Topcon, Japan), Keratograph 5M (Oculus, Germany) and aberrometer iTRACE (Hoya, Japan). Results: After 3 months were statistically compared keratometry values of ​​ corneal anterior surface detected by all devices. They provided to be comparable. Furthermore the values ​​of objective refraction and pachymetry were detected. Conclusion: Results of this study show a statistically significant correlation values ​​of objective refraction using devices TRK and iTRACE (r = 0.66 at p = 0.05) and showed a significant relationship between the keratometric data for all the devices. All used methods and devices are possible to reliably and use for valid evaluation parameters of the eye.</p>
      </abstract>
      <kwd-group>
        <kwd>aberrometry</kwd>
        <kwd>low and high orders abberations</kwd>
        <kwd>keratometry</kwd>
        <kwd>topography</kwd>
        <kwd>pachymetry</kwd>
      </kwd-group>
    </article-meta>
  </front>
</article>
