<?xml version="1.0" encoding="UTF-8"?>
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>Czech and Slovak Ophthalmology</journal-title>
      </journal-title-group>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">318</article-id>
      <article-id pub-id-type="doi">10.31348/2024/14</article-id>
      <article-categories>
        <subj-group>
          <subject>Original article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Comparison of Early Vision Quality of Sbl-2 and SBL-3 Segmented Refractive Lens</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Ratajová</surname>
            <given-names>Michaela</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Hoppeová</surname>
            <given-names>Veronika</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Janeková</surname>
            <given-names>Andrea</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-2644-4139</contrib-id>
        </contrib>
      </contrib-group>
      <pub-date date-type="pub" publication-format="electronic">
        <day>15</day>
        <month>3</month>
        <year>2024</year>
      </pub-date>
      <issue>2</issue>
      <elocation-id>4</elocation-id>
      <abstract>
        <p>Purpose: To compare objective quality of vision in patients undergoing phacoemulsification with implantation of a bilateral segmented multifocal intraocular lens (SMIOL). Methods: A retro-prospective study included 110 eyes of 55 patients who underwent cataract surgery with bilateral SMIOL implantation. Patients were divided according to the type of implanted intraocular lens into group 1 (SBL-2, 62 eyes) and group 2 (SBL-3, 48 eyes). Postoperatively, monocular and binocular uncorrected distance visual acuity (UCDVA), corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UCIVA, at 66 cm), uncorrected near visual acuity (UCNVA, at 40 cm), corrected near visual acuity (BCNVA) and defocus curve were measured and evaluated. The follow-up period was 6 months. Results: Mean UCDVA in group 1 (SBL-2) was 0.010 ±0.15 LogMAR monocularly, 0.01 ±0.10 LogMAR binocularly, and in group 2 (SBL-3) was 0.02 ±0.11 LogMAR monocularly and -0.07 ±0.09 LogMAR binocularly. Binocular defocus curves showed that the SBL-3 group performed better than the SBL-2 lens at a vergence of -1.50 D corresponding to 66 cm (center distance), averaging 0.03 ±0.11 LogMAR, while the SBL-2 group averaged 0.12 ±0.14 LogMAR (p = 0.01). The -2.50 D vergence characterizing near vision (40 cm) was achieved by the SBL-2 lens in our study at 0.33 ±0.15 LogMAR and by the SBL-3 lens at 0.00 ±0.11 LogMAR (p = 0.00). Conclusion: Both SMIOLs provided very good vision at all tested distances 6 months postoperatively. The SBL-2 lens performed better in UCIVA, while the SBL-3 lens excelled in UCDVA and UCNVA.</p>
      </abstract>
      <kwd-group>
        <kwd>rotationally asymmetric multifocal intraocular lens</kwd>
        <kwd>bifocal</kwd>
        <kwd>cataract</kwd>
        <kwd>visual acuity</kwd>
        <kwd>defocus curve</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="R1949">
        <mixed-citation>Sieburth R, Chen M. Intraocular lens correction of presbyopia. Taiwan J Ophthalmol. 2019 Jan-Mar;9(1):4-17.</mixed-citation>
      </ref>
      <ref id="R1950">
        <mixed-citation>Salerno LC, Tiveron MC Jr, Alió JL. Multifocal intraocular lenses: Types, outcomes, complications and how to solve them. Taiwan J Ophthalmol. 2017 Oct-Dec;7(4):179-184.</mixed-citation>
      </ref>
      <ref id="R1951">
        <mixed-citation>Wang X, Tu H, Wang Y. Comparative Analysis of Visual Performance and Optical Quality with a Rotationally Asymmetric Multifocal Intraocular Lens and an Apodized Diffractive Multifocal Intraocular Lens. J Ophthalmol. 2020 Apr 20;2020:7923045.</mixed-citation>
      </ref>
      <ref id="R1952">
        <mixed-citation>Woodward MA, Randleman JB, Stulting RD. Dissatisfaction after multifocal intraocular lens implantation. J Cataract Refract Surg. 2009 Jun;35(6):992-7.</mixed-citation>
      </ref>
      <ref id="R1953">
        <mixed-citation>Sachdev GS, Sachdev M. Optimizing outcomes with multifocal intraocular lenses. Indian J Ophthalmol. 2017 Dec;65(12):1294-1300.</mixed-citation>
      </ref>
      <ref id="R1954">
        <mixed-citation>Venter JA, Collins BM, Hannan SJ, Teenan D, Schallhorn JM. Outcomes of a Refractive Segmented Bifocal Intraocular Lens with a Lower Near Addition. Clin Ophthalmol. 2022 Aug;16:2531- 2543.</mixed-citation>
      </ref>
      <ref id="R1955">
        <mixed-citation>Xu Z, Cao D, Chen X, Wu S, Wang X, Wu Q. Comparison of clinical performance between trifocal and bifocal intraocular lenses: A meta-analysis. PLoS One. 2017 Oct 26;12(10):e0186522.</mixed-citation>
      </ref>
      <ref id="R1956">
        <mixed-citation>Zhao J, Liu LP, Cheng HH et al. Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens. Int J Ophthalmol. 2020 Sep 18;13(9):1378-1384.</mixed-citation>
      </ref>
      <ref id="R1957">
        <mixed-citation>Lian H, Ma W, Wei Q, Yuan X. A comparative study on early vision quality after implantation of refractive segmental and diffractive multifocal intraocular lens. Pak J Med Sci. 2020 Nov- Dec;36(7):1607-1612.</mixed-citation>
      </ref>
      <ref id="R1958">
        <mixed-citation>Hui N, Chu MF, Li Y, Wang CY, Yu L, Ma B. Comparative analysis of visual quality between unilateral implantation of a trifocal intraocular lens and a rotationally asymmetric refractive multifocal intraocular lens. Int J Ophthalmol. 2022 Sep 18;15(9):1460-1467.</mixed-citation>
      </ref>
      <ref id="R1959">
        <mixed-citation>Gil-Cazorla R, Shah S, Naroo SA. A review of the surgical options for the correction of presbyopia. Br J Ophthalmol. 2016 Jan;100(1):62- 70.</mixed-citation>
      </ref>
      <ref id="R1960">
        <mixed-citation>Serdiuk V, Ustymenko S, Fokina S, Ivantsov I. Comparison of three different presbyopia-correcting intraocular lenses. Rom J Ophthalmol. 2020 Oct-Dec;64(4):364-379.</mixed-citation>
      </ref>
      <ref id="R1961">
        <mixed-citation>Modi S, Lehmann R, Maxwell A, et al. Visual and Patient-Reported Outcomes of a Diffractive Trifocal Intraocular Lens Compared with Those of a Monofocal Intraocular Lens. Ophthalmology. 2021 Feb;128(2):197-207.</mixed-citation>
      </ref>
      <ref id="R1962">
        <mixed-citation>Alió JL, Plaza-Puche AB, Montalban R, Javaloy J. Visual outcomes with a single-optic accommodating intraocular lens and a low-addition-power rotational asymmetric multifocal intraocular lens. J Cataract Refract Surg. 2012 Jun;38(6):978-85.</mixed-citation>
      </ref>
      <ref id="R1963">
        <mixed-citation>Veliká V, Hejsek L, Raiskup F. Clinical Results of Implantation of Two Types of Multifocal Rotationally – Asymmetric Intraocular Lenses. Cesk Slov Oftalmol. 2017;73(1):3-12. Available from: https://www. cs-ophthalmology.cz/en/journal/articles/13</mixed-citation>
      </ref>
      <ref id="R1964">
        <mixed-citation>McNeely RN, Pazo E, Spence A et al. Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses. J Cataract Refract Surg. 2017 Aug;43(8):1020-1026.</mixed-citation>
      </ref>
      <ref id="R1965">
        <mixed-citation>McNeely RN, Pazo E, Spence A et al. Visual outcomes and patient satisfaction 3 and 12 months after implantation of a refractive rotationally asymmetric multifocal intraocular lens. J Cataract Refract Surg. 2017 May;43(5):633-638.</mixed-citation>
      </ref>
      <ref id="R1966">
        <mixed-citation>Oshika T, Arai H, Fujita Y, et al. One-year clinical evaluation of rotationally asymmetric multifocal intraocular lens with +1.5 diopters near addition. Sci Rep. 2019 Sep 11;9(1):13117.</mixed-citation>
      </ref>
      <ref id="R1967">
        <mixed-citation>Kretz FT, Khoramnia R, Attia MS, Koss MJ, Linz K, Auffarth GU. Clinical Evaluation of Functional Vision of +1.5 Diopters near Addition, Aspheric, Rotational Asymmetric Multifocal Intraocular Lens. Korean J Ophthalmol. 2016 Oct;30(5):382-389.</mixed-citation>
      </ref>
      <ref id="R1968">
        <mixed-citation>Pedrotti E, Mastropasqua R, Bonetto J et al. Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens. Int Ophthalmol. 2018 Aug;38(4):1709-1716.</mixed-citation>
      </ref>
      <ref id="R1969">
        <mixed-citation>Jing-Jing Q, Qian Z, Shu-Hua F et al. A comparison of the visual performance of refractive rotationally asymmetric multifocal intraocular lenses and trifocal intraocular lenses. Materials Express. 2023 Jun;13(6):1110-1115.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>